WS-9625U-IT 915 MHz WIRELESS WEATHER STATION Instruction manual

Seite 2 - TABLE OF CONTENTS

9 SETTING UP: When one sensor is to be used 1. First, insert the batteries into the thermo-hygro sensor. (see “Install and replace batteries in the

Seite 3

10 4. In order to ensure sufficient 915 MHz transmission however, this should under good conditions be a distance no more than 100 meters between t

Seite 4

11 displayed on the Weather Station. Also, the signal reception icon will be displayed. If this does not happen after 2 minutes, the batteries will

Seite 5 - Wireless Weather Station

12 sensor is successfully received. If this is not happen, user shall restart the setting up from step 1. Note: User shall insert the batteries i

Seite 6 - FEATURES:

13 IMPORTANT: Transmission problems will arise if the setting for additional sensors is not followed as described above. Should transmission probl

Seite 7

14 also updated with the received time. (Please refer also to notes on “Atomic time - WWVB Radio controlled Time” and “Manual Time Setting”) BATTE

Seite 8

15 INSTALL AND REPLACE BATTERIES IN THE THERMO-HYGRO SENSOR The sensor uses 2 x AA Alkaline batteries. To install and replace the batteries: 1. Remo

Seite 9 - • Wall mounting case

16 Note: In the event of changing batteries in any of the units, all units need to be reset by following the setting up procedures. This is because

Seite 10 - SETTING UP:

17 FUNCTION KEYS: Weather Station: The Weather Station has four easy to use function keys. SET key MIN/ MAX key + key CH key

Seite 11

18 SET key (Setting): • To enter the set mode for the following functions: LCD contrast, Time zone, Daylight saving time ON/ OFF, Time Reception ON

Seite 12

1 TABLE OF CONTENTS Topic Page Inventory of Contents 4 Features 5 Setting Up 8 Battery Installation 14 Function keys 17 LCD Screen and Settings 20

Seite 13

19 CH key • To toggle between the Outdoor Sensors 1, 2 and 3 (if more than 1 sensor is used) • To exit from the manual setting mode

Seite 14

20 LCD SCREEN AND SETTINGS: Indoor Relative Humidity % Weather Tendency icon Displays "date" or "second" Weather

Seite 15 - BATTERY INSTALLATION

21 *When the outdoor signal is successfully received by the Weather Station, this icon will be switched on. (If not successful, the icon will not be

Seite 16

22 Section 2 - INDOOR TEMPERATURE AND INDOOR HUMIDITY • Display the current indoor temperature and humidity. Section 3 - WEATHER ICON (FEATURING

Seite 17 - BATTERY CHANGE:

23 SECTION 5 – DAILY MIN AND MAX TEMPERATURE • Display the daily minimum and maximum temperature of the currently selected outdoor channel. ATOMI

Seite 18 - Weather Station:

24 measuring a second as 9,192,631,770 vibrations of a Cesium-133 atom in a vacuum. For more detail, visit http://www.boulder.nist.gov/timefreq.htm.

Seite 19

25 • Time reception ON/OFF setting • 12/24-Hour setting • Manual time setting • Calendar setting • °F/ °C setting • Weather forecasting icon s

Seite 20

26 The LCD contrast can be set to 8 different levels to suit the users’ needs (default LCD contrast setting is LCD 4). To set the desired contrast

Seite 21 - LCD SCREEN AND SETTINGS:

27 The time zone default is "EST -5". To set a different time zone: 1. The current time zone value starts flashing. 2. Use the + key to

Seite 22

28 1. The digit “DST ON” will start flashing on the LCD. 2. Use the + key to turn On or OFF the daylight saving time function. 3. Confirm with t

Seite 23

2 Display of Indoor Minimum and Maximum records 45 Display of Outdoor Minimum and Maximum records 48 Daily Min and Max outdoor temperature display

Seite 24

29 In area where reception of the Atomic time (WWVB time) is not possible, the time reception function can be turned OFF. The clock will then work

Seite 25 - MANUAL SETTINGS:

30 12/24 HOUR TIME DISPLAY SETTING 1. After setting time reception ON/OFF, press the SET key, “12h” or “24h” flashes in the LCD. (default 12

Seite 26

31 When 12h mode display is selected, the calendar format will be month and date display. MANUAL TIME SETTING In case the Weather Station is not ab

Seite 27

32 To set the clock: 1. The hour digits start flashing in the time display section. 2. Use the + key to adjust the hours and then press SET key to

Seite 28

33 CALENDAR SETTING Year "Date. Month." (for 24h time display) "Month. Date." (for 12h time display)

Seite 29 - Flashing

34 The date default of the Weather Station is 1. 1. of the year 2006 after initial set-up. Once the radio-controlled time signals are received, the

Seite 30

35 °F/°C TEMPERATURE UNIT SETTING The default temperature reading is set to °F (degrees Fahrenheit). To select °C (degrees Celsius): 1. The “°

Seite 31 - flashing

36 WEATHER FORECASTING ICON SENSITIVITY SETTING For locations with rapid changes of weather conditions, the threshold can be set to a different leve

Seite 32 - Hours (flashing)

37 1. Using the + key to set the weather sensitivity level. There are 3 levels of setting: 2, 3 and 4. The value corresponds to the change of air p

Seite 33

38 ≥ 78.8°F (26°C) 66.2 to 78.6°F (19 to 25.9°C) 50 to 66°F (10 to 18.9°C) 32 to 49.8°F (0 to 9.9°C) < 32°F (0°C) Sunny

Seite 34

3 This product offers: INSTANT TRANSMISSION is the state-of-the-art new wireless transmission technology, exclusively designed

Seite 35

39 ≥ 78.8°F (26°C) 66.2 to 78.6°F (19 to 25.9°C) 50 to 66°F (10 to 18.9°C) 32 to 49.8°F (0 to 9.9°C) < 32°F (0°C) Sunny + Cloudy

Seite 36

40 ≥ 78.8°F (26°C) 66.2 to 78.6°F (19 to 25.9°C) 50 to 66°F (10 to 18.9°C) 32 to 49.8°F (0 to 9.9°C) < 32°F (0°C) Cloudy + Rainy

Seite 37 - (flashing)

41 Note: After setting up, readings for weather forecasts should be disregarded for the next 48-60 hours. This will allow sufficient time for the We

Seite 38

42 mistake the new location as being a possible change in air-pressure when really it is due to the slight change of altitude. Again, disregard weat

Seite 39

43 Note: Once the weather tendency indicator has registered a change in air pressure, it will remain permanently visualized on the LCD. DISPLAY OF

Seite 40

44 DISPLAY OF OUTDOOR TEMPERATURE AND HUMIDITY READING: The outdoor temperature and humidity are measured and displayed on the fourth section of

Seite 41

45 DISPLAY OF OUTDOOR MINIMUM AND MAXIMUM RECORDS: 1. In normal display mode, press the CH button to select the desired channel. The channel I

Seite 42

46 Max icon Outdoor icon Time and date of recording the max temperature Channel No. Max temperature Max humidity

Seite 43

47 3. By pressing MIN/MAX button once more, the min temperature and humidity of the selected channel will be shown. Also the time and date of recor

Seite 44

48 2. Press the MIN/ MAX button once. The "max" icon will be displayed. 3. Press the SET button, this will reset the outdoor maximum tem

Seite 45

4 INVENTORY OF CONTENTS 1. Wireless Weather Station 2. Wireless Thermo-hygro Sensor (TX21U-IT) and mounting bracket. 3. Instruction Manual and

Seite 46

49 2. Then press the MIN/MAX button one more time, the minimum indoor temperature and humidity will be shown at the bottom section of LCD. Also the

Seite 47

50 3. Press one more time the MIN/ MAX button to go back to the normal display. RESETTING THE INDOOR MINIMUM /MAXIMUM RECORDS 1. In normal displ

Seite 48

51 DAILY MINIMUM AND MAXIMUM OUTDOOR TEMPERATURE DISPLAY This Weather Station will display the daily minimum and maximum outdoor temperature for eac

Seite 49

52 To view the daily minimum and maximum temperature of another channel, user shall press the CH key in normal display. Note: The daily minimum tem

Seite 50

53 3. Using other electrical products such as headphones or speakers operating on the same signal frequency (915MHz) may prevent correct signal tra

Seite 51

54 MOUNTING POSITIONING THE WEATHER STATION: The Weather Station may be hung onto wall easily or free standing. To wall mount Choose a sheltered pl

Seite 52

55 Free standing With the foldout stand, the Weather Station can be placed onto any flat surface.

Seite 53 - 915 MHz RECEPTION

56 POSITIONING THE THERMO-HYGRO SENSOR: The sensor is supplied with a holder that may be attached to a wall with the two screws supplied. The sens

Seite 54

57 To wall mount: 1. Secure the bracket onto a desired wall using the screws and plastic anchors. 2. Clip the remote thermo-hygro sensor onto th

Seite 55 - MOUNTING

58 CARE AND MAINTENANCE: • Extreme temperatures, vibration and shock should be avoided as these may cause damage to the unit and give inaccurate f

Seite 56

5 LCD Display FEATURES: The Weather Station Foldout Stand Battery compartment cover Function Keys Hanging hole

Seite 57

59 SPECIFICATIONS: Temperature measuring range: Indoor : 14.1°F to +139.8°F with 0.2°F resolution (-9.9ºC to +59.9ºC with 0.1ºC resolution,

Seite 58

60 Indoor temperature checking interval : every 15 seconds

Seite 59 - CARE AND MAINTENANCE:

61 WARRANTY La Crosse Technology, Ltd provides a 1-year limited warranty on this product against manufacturing defects in materials and workmanship.

Seite 60 - SPECIFICATIONS:

62 La Crosse Technology, Ltd and must be returned to La Crosse Technology, Ltd. Replacement parts and products assume the remaining original warran

Seite 61

63 someone other than an authorized La Crosse Technology, Ltd authorized service center; (6) units used for other than home use (7) applications and

Seite 62 - WARRANTY

64 the above exclusion of limitation may not apply to you. For warranty work, technical support, or information contact: La Crosse Technology, Lt

Seite 63

65 All rights reserved. This handbook must not be reproduced in any form, even in excerpts, or duplicated or processed using electronic, mechanical

Seite 64

6 • Atomic auto-set time (WWVB Radio controlled time) or manual time setting options • Atomic auto-set time reception ON/OFF setting • 12/24 hour

Seite 65

7 • Indoor and Outdoor temperature and humidity display with MIN/MAX recording • All MIN/MAX outdoor recordings show date and time received and al

Seite 66

8 The Outdoor Thermo-hygro Sensor • Remote transmission of outdoor temperature and humidity to Weather Station by 915 MHz • Shower proof casing •